Constant temperature and humidity box does not cool down

Yesterday I received a call from a customer in Shandong: They bought the constant temperature and humidity box purchased in Shanghai last August and kept it unused. Today, when the power is turned on, the temperature drop is less than -40 degrees. I don’t know what to do, of course I First suggest customers, equipment purchase is still within the warranty period, it is best to contact a manufacturer first (because the constant temperature and humidity equipment warranty period is generally 1 year, has not passed the warranty period), but the customer responded that at the time of purchase due to the price Very low, according to no warranty, I heard this sentence, I must be careful when purchasing equipment, choose a regular manufacturer, the following analysis by Henan Yunfei Technology Development Co., Ltd. for the constant temperature and humidity box does not cool down:

Failure phenomenon:
1, the temperature does not cool or does not heat up
2, the humidity can not be lowered or not added
3, refrigerant leakage
4, the refrigeration system is blocked (capillary blockage)

cause of issue:
1, 1 heat is not good, install the appropriate power of air conditioning in the equipment field to cool down or open the door and window to allow air to circulate 2 refrigeration system blockage, find the plugging point, replace the dry filter, add the refrigerant marked by the compressor, re-commission 3 Condensing fan is damaged, replace the condenser fan
2, 1 heat is not good 2 compressor damage, replace the same type of compressor, (preferably the same brand)
3The overcurrent protector is abnormal, the overcurrent protection is damaged, or the debugging is not good, resulting in the current setting being reduced.

Solution:
1. The compressor is damaged or not opened, replace the compressor and check whether the compressor circuit and control components are damaged or not. 2 refrigerant leakage, use nitrogen leak detection method to find the leak point, weld, vacuum, add refrigerant, re Debug 3 solenoid valve abnormal operation, replace the solenoid valve, check the solenoid valve control line 4 capillary blockage, replace the capillary, replace the dry filter, purge the condensing system impurities with nitrogen, add refrigerant debugging 5 condenser icing, heat drying box Internal moisture, cooling
2, 1 heating tube is damaged (replaceable)
2 solid state relay is damaged, you can replace it
3, 1 humidification pipe damage, replacement can be 2 control humidification water level float ball does not float 3 humidification solid state relay damage

Metal Packaging


The Anomatic series of high-quality deep drawn Aluminum Canisters is designed to be compatible with your chosen valves, Actuators and drug formulations. Our deep drawing process ensures a consistent side wall thickness using high strength aluminum which is far superior to other forming methods. The aluminum is work hardened during the deep draw process and the surface mechanically polished providing a smooth, hard internal finish suitable for use with both CFC and HFA propellants.

Our standard canister sizes are 10ml, 14ml and 19ml, with customized sizes available. Our canisters are also available in anodized and plasma coated finishes.

Why Anomatic

Headquartered in New Albany, Ohio (USA), Anomatic is the world`s leading supplier of anodized aluminum solutions and offers:

· U.S. and Asia based manufacturing

· State-of-the-art facilities

· Unmatched capacity at 2.5 billion units annually

· cGMP compliant and ISO14001 and ISO9001 certified

· Advanced surface treatment options

· Unrivaled lead times

Anomatic's patented continuous anodizing process creates a smooth, uniform anodized finish that completely covers the inside of the canister, providing a protective barrier for many sensitive formulations.

Aluminum anodization is an electrochemical process that enhances the strength, durability, and appearance of aluminum. When aluminum is oxidized, super-strong oxide (anodic) layers [grow" on the surface of the metal. These new layers are highly resistant to wear and corrosion.

The exacting part to part consistency achieved with our unique anodizing system cannot be obtained with conventional hoist line systems. Conventional anodizing systems present parts with varied coating thicknesses and voids formed due to air pocketing.

A consistent uniform 6 µm anodic film thicknesses will protect certain drug formulations and the canister from degradation. Heavier film thicknesses of up to 12µm can be provided to meet your more demanding application.


Asthma Metered doses inhaler,Metal Packaging,Ray Canister Metered Dose Inhaler can

Anomatic(suzhou)metal packaging co,ltd , https://www.anomaticpharma.com