1. The vacuum machine should be used in an environment where the relative humidity is ≤ 85% RH, there is no corrosive gas around, no strong vibration source and strong electromagnetic field.
2. The vacuum machine casing must be effectively grounded to ensure safe use.
3, the vacuum pump can not work for a long period of time, so when the vacuum reaches the requirements of dry goods, the vacuum valve should be closed first, then the vacuum pump power supply should be turned off. When the vacuum is less than the requirements of the dry goods, then the vacuum valve and the vacuum pump power supply are turned on, and the vacuum is continued. This will extend the life of the vacuum pump.
4. If the dry items are wet, add a filter between the vacuum machine and the vacuum pump to prevent the humid gas from entering the vacuum pump and causing the vacuum pump to malfunction.
5, the vacuum machine studio is not explosion-proof, anti-corrosion treatment, and should not be placed in flammable, explosive, and easily corrosive gases for drying.
6. After the vacuum machine is used for many times, it will not be able to vacuum. In this case, the door seal should be replaced or the door buckle on the body should be adjusted to extend the distance. When the drying temperature of the vacuum machine is higher than 200 °C, it will produce slow air leakage (except 6050, 6050B, 6051, 6053). At this time, remove the heater base and replace the sealing ring with the Allen key on the back cover of the boot body. Or tighten the heater base to solve.
7. Dry items should be light weight and small in size (small granular shape) after drying. Vacuum should be added to the working chamber to prevent the vacuum pump (or solenoid valve) from being inhaled by the dry matter.
8. If the rubber plug of the bleed valve is difficult to rotate, it can be lubricated with a proper amount of grease on the inside. (such as Vaseline)
9. The vacuum machine should always be kept clean. Do not wipe with a reactive chemical solution and wipe with a soft cotton cloth.
10. In addition to maintenance, the body cannot be removed to avoid damage to the electrical control system.
11. When the vacuum machine does not need continuous pumping, the vacuum valve should be closed first, then the vacuum pump power supply should be turned off, otherwise the vacuum pump oil should be poured into the box.
12. If the vacuum machine is not used for a long time, wipe the exposed plating parts and apply neutral grease to prevent corrosion. Put on the plastic film dust cover and place it in the dry room to avoid damage to the electrical components. use.